Code:SGLZ
Cable Size:
Description:SGLZ-125A~1600A.The load isolation switch is suitable for the change-over of two sets of low voltage electric circuit or the chang-over of 2 set of load devices or safety isolation.
SGLZ-125A~1600A change over load isolation switch
SGLZ-125A~1600A.The load isolation switch is suitable for the change-over of two sets of low voltage electric circuit or the chang-over of 2 set of load devices or safety isolation.
Mode of operation:
Direct operation:handle is installed on the switch.
Operation outside the board:handle is installed outside the door of power distributing board.
Products with observation windows can be provided according to the demand to obsvrve directly the ON and OFF state of contact.
The products have three poles,four poles,and(three pole+ON and OFF neural pole).
Extended shate is used for ther operation outside the board.
Two sets of auxiliary contacts can be assembled according to the demand.
Mechanical performance and electric property correspond to the mechanical performance and elextric property of SGL-125A-1600A.
A bridge can provided to connect the inlet or outlet terminal of the switch.
Note:The bridge connection is chosen,an explanation is needed to indicate ther indicate the inlet or outlet connected with it.
The characterisitc(conforms to the GB14048.3-2002/IEC60947-3 standard)
Conventional thermal current lth A(40℃) | 125A | 160A | 200A | 250A | 400A | 630A | |
Rated impulse withstand voltage Ui(V) | 800 | 800 | 800 | 800 | 800 | 1000 | |
Rated striling voltage Uimp(KV) | 8 | 8 | 8 | 8 | 8 | 12 | |
Rated operation currentel(A) | |||||||
Rated voltage | overload type | A/B(1) | A/B(1) | A/B(1) | A/B(1) | A/B(1) | A/B(1) |
400VAC | AC-21A/AC-21B | 125/125 | 160/160 | 200/200 | 250/250 | 400/400 | 630/630 |
AC-22A/AC-22B | 125/125 | 160/160 | 200/200 | 250/250 | 400/400 | 630/630 | |
AC-23A/AC-23B | 125/125 | 160/160 | 160/160 | 250/250 | 250/250 | 500/600 | |
690VAC(2) | AC-20A/AC-20B | 125/125 | 160/160 | 200/200 | 250/250 | 400/400 | 630/630 |
AC-21A/AC-21B | 125/125 | 160/160 | 160/160 | 200/250 | 200/250 | 500/500 | |
AC-22A/AC-22B | 125/125 | 125/125 | 125/125 | 125/160 | 125/160 | 315/315 | |
AC-23A/AC-23B | 63/80 | 63/80 | 63/80 | 100/125 | 100/125 | 160/200 | |
220VDC | DC-20A/DC-20B | 125/125 | 125/125 | 200/200 | 250/250 | 400/400 | 630/630 |
DC-21A/DC-21B | 125/125 | 125/125 | 160/160 | 250/250 | 250/250 | 630/630 | |
DC-22A/DC-22B | 125/125 | 1, 25/125 | 160/160 | 250/250 | 250/250 | 500/500 | |
DC-23A/DC-23B | 125/125 | 125/125 | 125/125 | 200/200 | 200/200 | 500/500 | |
440VDC | DC-20A/DC-20B | 125/125 | 125/125 | 200/200 | 250/250 | 400/400 | 630/630 |
DC-21A/DC-21B | 125/125 | 125/125 | 125/125 | 200/200 | 200/200 | 500/500 | |
DC-22A/DC-22B | 125/125 | 125/125 | 125/125 | 200/200 | 200/200 | 500/500 | |
DC-23A/DC-23B | 125(3)/80 | 125(3)/80 | 125(3)/125(3) | 200(3)/200(3) | 200(3)/200(3) | 500(3)/500(3) | |
operation power | No break down under 400VAC | 63/63 | 80/80 | 80/80 | 132/132 | 132/132 | 280/280 |
No break down under 690VAC | 55/75 | 55/75 | 55/75 | 90/110 | 90/110 | 150/185 | |
Reactive power | 400VAC (kvar) | 55 | 75 | 90 | 115 | 185 | 290 |
Uses the fuse short-circuit current condition(the Karms required value) | required short-circuit current value | 100 | 100 | 50 | 50 | 8 | 70 |
Fuse Capacity | 125 | 160 | 200 | 250 | 400 | 630 | |
Short-circuit capability | lcw(KArms)Allowed short time endure current | 7 | 7 | 7 | 9 | 9 | 13 |
Short-cicuit dynamic intensity | 20 | 20 | 20 | 30 | 30 | 45 | |
Connection | Minimal copper cable section | 35 | 50 | 50 | 95 | 185 | 2×150 |
Minimal copper row width | 2×30×5 | ||||||
Maximal copper cable section | 50 | 95 | 95 | 150 | 240 | 2×300 | |
Maximal copper row width | 25 | 25 | 25 | 32 | 32 | 50 | |
Minimal tighten wrest distance | 9 | 9 | 9 | 20 | 20 | 20 | |
Machanism Characteristic | Life(operation cycle times) | 10000 | 10000 | 10000 | 10000 | 10000 | 5000 |
3pole switch weight(kg) | 1.5 | 1.6 | 1.8 | 2 | 3 | 3.5 | |
4pole switch weight(kg) | 1.6 | 1.7 | 1.9 | 2.1 | 3.5 | 4 |
Conventional thermal current lth A(40℃) | 800A | 1250A | 1600A | 1800A | 2000A | 2500A | 3150A | |
Rated impulse withstand voltage Ui(V) | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | |
Rated striling voltage Uimp(KV) | 12 | 12 | 12 | 12 | 12 | 12 | 12 | |
Rated operation currentel(A) | ||||||||
Rated voltage | overload type | A/B(1) | A/B(1) | A/B(1) | A/B(1) | A/B(1) | A/B(1) | A/B(1) |
400VAC | AC-21A/AC-21B | 800/800 | 1250/1250 | 1600/1600 | 1800/1800 | 2000/2000 | 2500/2500 | 3150/3150 |
AC-22A/AC-22B | 800/800 | 1250/1250 | 1600/1600 | 1800/1800 | 2000/2000 | 2000/2500 | 2500/2500 | |
AC-23A/AC-23B | 800/800 | 1250/1250 | 1250/1250 | 1250/1250 | 1250/1250 | 1250/1250 | 1250/1250 | |
690VAC(2) | AC-20A/AC-20B | 800/800 | 1250/1250 | 1600/1600 | 1800/1800 | 2000/2000 | 2500/2500 | 3150/3150 |
AC-21A/AC-21B | 800/800 | 800/800 | 1000/1000 | 1000/1000 | 2000/2000 | 2000/2500 | 2000/2500 | |
AC-22A/AC-22B | 800/800 | 200/500 | 1000/1000 | 1000/1000 | 1000/1000 | 1000/1000 | 1000/1000 | |
AC-23A/AC-23B | 200/250 | 1250/1250 | 500/500 | 500/500 | 800/800 | 800/800 | 800/800 | |
220VDC | DC-20A/DC-20B | 800/800 | 1250/1250 | 1600/1600 | 1800/1800 | 2000/2000 | 2500/2500 | 3150/3150 |
DC-21A/DC-21B | 800/800 | 1250/1250 | 1250/1250 | 1250/1250 | 2000/2000 | 2000/2500 | 2000/2500 | |
DC-22A/DC-22B | 800/800 | 1250/1250 | 1250/1250 | 1250/1250 | 1250/1600 | 1250/1600 | 1250/1600 | |
DC-23A/DC-23B | 800/800 | 1250/1250 | 1250/1250 | 1250/1250 | 1250(3)/1250(3) | 1250(3)/1250(3) | 1250(3)/1250(3) | |
440VDC | DC-20A/DC-20B | 800/800 | 1250(3)/1250(3) | 1600/1600 | 1600/1600 | 2000/2000 | 2000/2000 | 3150/3150 |
DC-21A/DC-21B | 800/800 | 1250(3)/1250(3) | 1250(3)/1250(3) | 1250(3)/1250(3) | 1250/1250 | 1250/1250 | 1250/1250 | |
DC-22A/DC-22B | 800/800 | 1250(3)/1250(3) | 1250(3)/1250(3) | 1250(3)/1250(3) | 1250(3)/1250(3) | 1250(3)/1250(3) | 1250(3)/1250(3) | |
DC-23A/DC-23B | 800(3)/800(3) | 1250(3)/1250(3) | 1250(3)/1250(3) | 1250(3)/1250(3) | 1000(3)/1000(3) | 1000(3)/1000(3) | 1000(3)/1000(3) | |
operation power | No break down under 400VAC | 450/450 | 710/710 | 710/710 | 710/710 | 710/710 | 710/710 | 710/710 |
No break down under 690VAC | 185/220 | 185/220 | 475/475 | 475/475 | 750/750 | 750/750 | 750/750 | |
Reactive power | 400VAC (kvar) | 365 | 575 | - | - | - | - | - |
Uses the fuse short-circuit current condition(the Karms required value) | required short-circuit current value | 50 | 100 | 100 | 100 | 100 | 100 | 100 |
Fuse Capacity | 800 | 1250 | 2×800 | 2×800 | 2×1000 | 2×1000 | ||
Short-circuit capability | Allowed short time endure current | 26 | 35 | 50 | 50, | 50 | 50 | 55 |
Short-cicuit dynamic intensity | 55 | 80 | 110 | 110 | 110 | 110 | 120 | |
Connection | Minimal copper cable section | 2×185 | ||||||
Minimal copper row width | 2×40×5 | 2×60×5 | 2×80×5 | 2×80×5 | 3×100×5 | 4×100×5 | 4×100×5 | |
Maximal copper cable section | 2×300 | 4×185 | 6×185 | 6×185 | ||||
Maximal copper row width | 63 | 63 | 100 | 100 | 125 | 125 | 125 | |
Minimal tighten wrest distance | 40 | 40 | 40 | 40 | 40 | |||
Machanism Characteristic | Life(operation cycle times) | 3000 | 3000 | 4000 | 4000 | 3000 | 3500 | 2500 |
3pole switch weight(kg) | 17.5 | 22.5 | 34 | 34 | 70 | 72 | 98 | |
4pole switch weight(kg) | 21 | 27.5 | 42 | 42 | 85 | 88 | 110 |